Skip to content
ANTRONI · ARCHITECTURAL WINDOW & DOOR SYSTEMS
ANTRONI

System
configuration.

Explore the frame, timber, glazing and hardware that make up an ANTRONI window or door.

Detail of a dark ceramic-coated aluminium profile

01 / Frame system

Frame system

Alloy selection, structural design and ceramic coating.

Alloy properties

PROFILE MATERIAL

6060-T6

Tensile strength · MPa
210–245
Yield strength · MPa
180–220
Aluminium alloy stock
Aluminium alloy stock
6060-T6 material properties
6060-T6 material properties · presentation reference
PropertyReference value
Tensile strength210–245 MPa
Yield strength180–220 MPa
Elongation6–10%
Corrosion resistanceGood
Surface treatabilityGood

Structural design

ENGINEERING

Connections and calculations

Pinned corner joints, reinforced mullions and stiffening ribs are considered together. The presentation also shows a flush frame detail to reduce protruding edges. Project calculations account for the site, installation height and local wind pressure.

Pinned corner joints and profile reinforcement
Pinned corner joints and profile reinforcement
Structural details and calculations
Reinforced mullions
Reinforcement is concentrated at key load-bearing points, based on the opening dimensions and glazing divisions.
Pinned corner joints
Pinned connections keep adjoining profiles together at frame corners.
Stiffening ribs
Ribs within the profile section add support at the relevant locations.
Connection details and excerpt from the wind-load calculations in the original presentation
Structural connection and wind-load calculation · Technical reference

Project-specific structural checks

The lead technical engineer prepares door and window calculation reports from the design drawings, checking strength, deflection, stability and shear. The engineering examples cover large curtain-wall glazing and profiles at ultra-slim curtain-wall openings.

Wind-load calculation basis

wk = βgz · μs1 · μz · w0

Gust factor × local shape factor × height variation factor × reference wind pressure. The calculation uses the conditions and dimensions of the opening under review.

Surface treatment

SURFACE FINISH

Ceramic electrophoretic finish

An anodised film and an electrophoretic coating form a composite finish. The resulting surface is finely textured and matte.

Coating thickness · presentation reference
≥ 18 μm
Matte finish on black aluminium profiles
Matte finish on black aluminium profiles
Surface finish comparison
Finish comparison · presentation reference
PropertyCeramic electrophoretic finishPowder coating
Coating thickness≥ 18 μm≥ 60 μm
Coating structureComposite anodised and electrophoretic filmsDense, even coating with strong substrate adhesion
Corrosion resistanceAlkali and corrosion resistance for humid environments such as coastal areasCorrosion protection for typical industrial and residential applications away from the coast
Outdoor weatheringThe report lists 20 years without fading, with UV resistance and stable colourThe report lists 10–15 years for outdoor use
Surface and feelHard, fine matte surface with diffuse reflection and limited dust build-upDurable surface with flexibility in design and cost
Colour and textureFine ceramic-like textureCustom colours across a wide palette

Weathering figures are from the presentation. Actual finish life depends on exposure and maintenance.

02 / Timber system

Timber system

Timber species, finishes and the standard red oak specification.

Compare the standard red oak with two optional timbers from the reference configuration.

North American red oak

Standard configuration

North American red oak

Hard and stable, with a pronounced grain. The reference configuration uses North American red oak as standard.

North American red oak
North American red oak

Russian larch

Optional timber

Russian larch

A tough timber with some natural decay resistance. Thorough drying helps control movement.

Russian larch
Russian larch

Burmese teak

Optional timber

Burmese teak

Naturally oil-rich, with a fine grain and good resistance to wear and decay.

Burmese teak
Burmese teak

TEKNOS / Timber finish

Teknos water-based coating

A water-based finish preserves the natural grain and helps protect the timber and its colour.

Explore aluminium–wood systems
Coating process steps
13
Drying method
Natural air drying
Coordinate material and architectural style

Coordinate the frame with the façade and the interior. French designs can align openings around a clear axis, use symmetrical compositions, and echo arches or curves through the glazing divisions and ornament.

Material character and architectural expression
MaterialCharacter
Solid timberA substantial appearance and visible natural grain.
Thermally broken aluminiumA modern appearance with controlled frame lines.
Aluminium–woodExterior aluminium coordinated with the façade, with timber character inside.
Steel windowsSlender lines for a light architectural expression.
Symmetrical French façade with arched glazing and decorative details
French architectural composition
Door and window materials within different interiors
Material character in interiors

03 / Glazing system

Glazing system

Thermal insulation, acoustic performance, clarity and privacy.

Glazing selection and strength calculations

Confirm the opening, climate, wind pressure and seismic loading before selecting glass thickness and support. Calculation software checks the glass dimensions, build-up and boundary conditions against the project requirements.

Thermal

Insulation and heat transfer

The insulating cavity, argon fill and Low-E coating address different heat-transfer paths.

Conduction

Conduction

Heat moves through solids. The insulating cavity and low-conductivity warm edge reduce heat transfer.

Insulating glass and warm-edge spacer: Conduction GlassGlass Argon cavity Low-E coating 4SG warm-edge spacer
Heat-transfer paths. Diagram not to scale.

Convection

Convection

Heat moves with the motion of a fluid. Filling the cavity with argon helps limit heat transfer across it.

Insulating glass and warm-edge spacer: Convection GlassGlass Argon cavity Low-E coating 4SG warm-edge spacer
Heat-transfer paths. Diagram not to scale.

Radiation

Radiation

Heat travels by electromagnetic waves. The Low-E coating helps reduce radiant heat transfer.

Insulating glass and warm-edge spacer: Radiation GlassGlass Argon cavity Low-E coating 4SG warm-edge spacer
Heat-transfer paths. Diagram not to scale.
Triple glazing · two cavities
≈ 1.0 W/(m²·K)

Reference K-value for a three-pane, two-cavity glazing build-up.

4SG warm-edge spacer
0.3 W/(m·K)

Warm-edge material conductivity. The spacer forms a chemical bond with glass and silicone sealant.

Reading the thermal figures

The K-value applies to the reference glazing build-up, and the conductivity applies to the spacer material. Whole-window thermal performance depends on the complete assembly.

The report text gives 90% argon fill and its diagram shows ≥95%. Confirm the fill ratio for the selected glazing.

4SG warm-edge glazing detail
4SG warm-edge glazing detail
Low-E and aluminium–wood thermal references

Low-E coatings limit radiant heat transfer. The aluminium–wood selection guide lists 80–95% reflection of mid- and far-infrared radiation for its coating example. Single-, double- and triple-silver coatings have different transmission and reflection curves.

The same guide lists a K-value below 1.4, 90% argon fill and 25-year long-term sealing for its example. The K-value summary omits the unit and applies to that selection example. Whole-window ratings follow the complete assembly. Timber’s low conductivity also helps limit heat transfer through an aluminium–wood frame.

Acoustics

Glazing acoustics

Sound travels through gases, liquids and solids. Insulating cavities, PVB interlayers and panes of differing thicknesses provide different approaches to traffic, shipping and voice noise.

Insulating glass unit Spacer Argon Glass
Insulating glass unit
Laminated insulating glass Spacer Argon Glass PVB interlayer
Laminated insulating glass

The laminated insulating unit shown uses three glass panes, one insulating cavity and a PVB interlayer. Triple glazing with two cavities has a different build-up.

Reference acoustic measurements for 12 glazing build-ups (dB)
Glazing typeBuild-upRRw (C; Ctr)
Single glazing12 mm32.933 (−2; −3)
Single-cavity insulating glass6 mm + 12 A + 6 mm34.135 (−1; −3)
Single-cavity insulating glass8 mm + 12 A + 8 mm35.836 (0; −2)
Double-cavity insulating glass6 mm + 12 A + 6 mm + 12 A + 6 mm37.737 (−1; −3)
Vacuum glazing6 mm + 0.3 V + 6 mm—38 (−1; −2)
Vacuum insulating composite6 mm + 0.3 V + 6 mm + 12 Ar + 6 mm—40 (−1; −4)
Laminated glass4 mm + 0.76 PVB + 4 mm36.136 (0; −1)
Laminated glass6 mm + 0.76 PVB + 6 mm38.437 (−1; −2)
Laminated glass6 mm + 1.52 PVB + 6 mm39.937 (−1; −4)
Laminated glass8 mm + 1.52 PVB + 8 mm41.638 (0; −2)
Laminated insulating glass5 mm + 9 Ar + 3 mm + 0.76 PVB + 3 mm38.838 (−1; −3)
Laminated insulating glass8 mm + 0.76 PVB + 3 mm + 24 A + 4 mm + 0.76 PVB + 4 mm45.043 (0; −2)

V = vacuum, A = air, Ar = argon. Rw (C; Ctr) values follow the test conditions of the listed reference build-ups. A dash means the source does not list a value.

Additional glazing selection examples

The sound transmission diagram uses two reference examples, STC 32 and STC 45. These STC labels are separate from the sound insulation values in dB below and the R and Rw measurements above; the figures are not converted or treated as equivalent.

Brochure reference examples · glazing build-ups and performance
Glazing typeBuild-up (brochure notation)Sound insulation (dB)Energy performanceHigh-rise safety
Single pane629——
Insulating glass6-12-635Noticeable effectTypical
Triple glazing, two cavities6-12-6-12-639Strong effectTypical
Laminated glass6/1.52/639No noticeable effectMarked
Laminated insulating glass6-12-6/1.52/642Noticeable effectMarked
Double-laminated insulating glass6/1.52/6-12-6/1.52/643Noticeable effectMarked

The six examples retain the brochure notation, sound insulation values and qualitative comparisons. The sound insulation column does not identify an Rw or STC test rating. Energy performance and high-rise safety are qualitative references; the project specification follows the complete glazing build-up and its calculation or test results.

Visual quality

Visual quality and privacy

Low-iron glass

Low-iron glass

Low-iron glass is selected for high light transmission. The finished glazing combines daylight requirements with the appropriate safety build-up.

Low-iron glass
Low-iron glass
Compare light transmission and glass safety

The low-iron glass samples shown transmit 91.0–91.6% of visible light. Insulated, laminated and coated assemblies have their own transmittance, which depends on the full build-up.

Visible light transmittance · clear and low-iron glass samples
Thickness (mm)Clear glass (%)Low-iron glass (%)
390.391.6
589.491.5
688.991.3
887.991.3
1087.091.1
1286.091.0

Heat soaking is an additional treatment used to reduce the risk of spontaneous breakage in tempered glass. Glass strength is checked separately against the project loads and dimensions.

Optical quality

High-quality glass substrates

Flatness and image clarity guide glass selection. Optical distortion depends on the finished glazing.

High-quality glass substrates
High-quality glass substrates

Privacy

Integrated blinds

Adjustable blinds between the panes let occupants control daylight and privacy.

Integrated blinds
Integrated blinds

Decorative glass

Colour and decorative glazing

Frame colours can be matched to Pantone references and coordinated with the room. Decorative glass can be made for the shape of the opening and the coloured light required by the design.

Decorative glass samples in yellow, green and blue with arched and rounded shapes
Decorative glass · Shape and colour
Coloured glazing casting patterned light on an interior floor
Decorative glass · Interior effect

Project case

GLAZING / CONFIGURATION EXAMPLE

Glazing configuration example

The original proposal selected a laminated insulating unit with an outer tempered pane, an argon cavity and two inner panes laminated with PVB.

  1. 6 mm
    Tempered glass
  2. 12 Ar
    Argon cavity
  3. 6 mm
    Glass
  4. 1.52 PVB
    Lamination
  5. 6 mm
    Glass
R
43.0 dB
Rw (C; Ctr)
43 dB (−2; −4)

Build-up: 6 + 12Ar + 6 + 1.52PVB + 6. The sound reduction figures above are values cited for the proposed glazing build-up.

Open- and closed-window readings

North · street traffic

Window open · approx. 71 dB
Window open · approx. 71 dB
Window closed · approx. 57 dB
Window closed · approx. 57 dB

South · renovation noise

Window open · approx. 69 dB
Window open · approx. 69 dB
Window closed · approx. 47 dB
Window closed · approx. 47 dB

04 / Hardware system

Hardware system

Handles, pivots and hardware matched to each opening type.

Handles, pivots and transmission

Pivot
Solid-brass load-bearing assembly
Handles
Custom minimalist forms
Finish options
Antique brass, matte black and brushed nickel
Three ANTRONI minimalist handles from the original presentation
Custom hardware forms and finishes

Choose the handle form alongside its operation and the surrounding materials. Antique brass, matte black and brushed nickel offer different surface character for French and contemporary interiors.

Eight vintage hardware forms with different handle shapes and finishes
Hardware forms and finish options

05 / Performance and materials

Performance and materials

System performance, core materials, installation and service.

Select the opening around its function and appearance, then resolve the material schedule, installation and service conditions.

Functional selection considers safety, wind resistance, watertightness, airtightness, acoustic comfort, thermal comfort, privacy and smart controls. Architectural and interior style guide the frame form, colours and surface choices.

Performance comparison

Thermal conductivity

A low-conductivity 4SG warm edge helps limit heat flow at the glazing perimeter.

Thermal conductivity reference values
Materialλ · W/(m·K)
Aluminium160
Steel50
Stainless steel17
Glass1
Timber0.043
4SG warm-edge material0.3

These values describe the listed materials. Glass and whole-window thermal transmittance use a different measurement.

System performance

Three system types · technical reference comparison
ComparisonStandard aluminium windowsUltra-slim energy-efficient aluminium windowsAluminium-clad timber doors and windows
Whole-window thermal reference · W/(m²·K)≤2.8≤2.0≤1.0
Window frame · Model series60–65 series70–75 series and above80 series and above
Window frame · Sealing layersDouble sealTriple sealTriple seal
Profile thermal transmittance · W/(m²·K)>3.02.2–2.51–1.3
Glazing systemStandard insulating glassLow-E insulating glass or standard triple insulating glassLow-E triple glazing with two argon-filled cavities
Glazing thermal transmittance · W/(m²·K)2.7–2.91.4–1.70.8–1.0

Reference comparison. Confirm performance data, test methods and local requirements for the selected product and project.

Core materials

This material schedule lists ten material brands, specifications and origins. Supply and configuration follow the project documents.

Material brands and specifications
MaterialBrand / specificationOrigin
Aluminium profileYinghui, GuangdongGuangdong, China
Timber profileNorth American red oakNorth America
Aluminium coatingAkzo NobelNetherlands
HardwareROTO / Stanfo / solid-brass pivotsGermany / bespoke
HandlesROTO / bespoke / solid-brass handlesGermany / bespoke
4SG high-efficiency glazingPenghaoChina
4SG flexible warm-edge spacerKömmerlingGermany
Thermal breakTechnoformGermany
Sealing gasketJiangyin HAIDAChina
Weatherproof sealantBaiyun, GuangzhouChina

Installation and service

Equipment for handling and positioning

Choose handling equipment around the site, frame dimensions and glass weight, then coordinate installation, protection and acceptance.

Mechanical equipment positioning large glazing at a building opening
Glazing installation
Handling equipment
  • Excavators prepare complex sites; cranes provide stable vertical lifting.
  • Heavy forklifts move profiles and glass while limiting scratches and impacts from manual handling.
  • Powered vacuum handling arms grip and finely position glass or frames weighing several hundred kilograms, with millimetre-level positioning described in the installation system.
Installation and acceptance
Installation process and checks
StageWork and checks
Standardised proceduresAgree the installation sequence, tolerances, fixings and inspection points for the actual opening and substrate.
Site coordinationRecord opening dimensions and coordinate embedded parts, waterproofing and load-bearing interfaces with the local team.
AcceptanceDefine checks for fixings, seals, drainage, glazing and operation, and retain the agreed inspection records.
ProtectionAgree protection for glass, finishes, handles and tracks during transport, installation and the remaining building work.
Tools and auxiliary materials

Select the specified Würth tools and auxiliary materials around the installation method, access and site conditions.

Check the exact item, test method and documented scope before using a report as evidence for the project.

Assess auxiliary materials against site exposure, compatibility with adjoining materials and applicable local requirements.

Project and installation team
Project and installation roles
RoleResponsibilities to agree
Project leadAgree who is responsible for project requirements, scope, programme and communication.
Specialist technical consultantIdentify who reviews calculations, specifications, interfaces and the requirements applicable to the project.
Resident engineerAssign coordination of measured openings, anchors, waterproofing and site constraints.
Installation crewConfirm who installs, inspects, records and hands over the system under the agreed procedures.
Warranty and follow-up service
Product warranty and service coverage
SystemTerm and coverage
Glass unitsConfirm the eligible glass unit, covered failure modes, duration and exclusions in the terms agreed for the project and market.
Operating hardwareHardware test reference: 100,000 opening and closing cycles for the documented item. Confirm the selected hardware, test method and warranty terms for your project.
Waterproofing systemAgree responsibility for joints, building interfaces, maintenance and any water-leak remediation in the project documents.

Coverage, duration, exclusions and service scope follow the signed project documents and the terms applicable to the destination market.

CLIMATE & PERFORMANCE

Climate, comfort and lasting use.

From solar gain to ongoing care, a window specification should respond to the place and the way a building is used.

Solar control & daylight

Balance daylight and views with solar heat gain. Review glass SHGC/g-value alongside façade orientation and external shading, especially where cooling demand is a priority.

Whole-system thermal performance

Consider the complete window or door: frame, glazing, spacers and seals. Assess its U-value together with air-leakage performance and installation details.

Durability & care

Select finishes, hardware and sealing details for the site’s exposure. Plan access for cleaning, drainage checks and routine maintenance from the outset.

Performance depends on the final configuration and project conditions. Confirm values against applicable test reports and project calculations.

Explore technical configurations

System comparison

Search